English
English
Español
Português
русский
français
日本語
Deutsch
Tiếng Việt
Italiano
Nederlands
ไทย
Polski
한국어
Svenska
magyar
Malay
বাংলা
Dansk
Suomi
हिन्दी
Pilipino
Türk
Gaeilge
عربى
Indonesia
norsk
اردو
čeština
Ελληνικά
Українська
Javanese
فارسی
தமிழ்
తెలుగు
नेपाली
Burmese
български
ລາວ
Latine
Қазақ
Euskal
Azərbaycan
slovenský
Македонски
Lietuvos
Eesti Keel
Română
Slovenski
मराठी
Српски
Esperanto
Afrikaans
Català
עִברִית
Cymraeg
Galego
Latvietis
icelandic
יידיש
Беларус
Hrvatski
Kreyòl ayisyen
Shqiptar
Malti
lugha ya Kiswahili
አማርኛ
Bosanski
Frysk
ជនជាតិខ្មែរ
ქართული
ગુજરાતી
Hausa
Кыргыз тили
ಕನ್ನಡ
Corsa
Kurdî
മലയാളം
Maori
Монгол хэл
Hmong
IsiXhosa
Zulu
Punjabi
پښتو
Chichewa
Samoa
Sesotho
සිංහල
Gàidhlig
Cebuano
Somali
Точик
O'zbek
Hawaiian
سنڌي
Shinra
հայերեն
Igbo
Sundanese
Lëtzebuergesch
Malagasy
Yoruba
Javanese
Banbala
Pokjoper
Divih
Philippine
Gwadani
Elokano
Explosion-proof intermediate junction boxes include explosion-proof straight junction boxes (commonly known as two-way) and explosion-proof T-type junction boxes (commonly known as three-way). It is mainly used in the connection of electric heating cables in explosion-proof areas to increase the length of electric heating cables, or to use different power heating cables and trident tubes on the same pipeline and other complex occasions. Its shell is made of DMC plastic.
JHE-L-GET
End termination kit with LED signal lamp for industrial trace heating applications.
Features
The JHE-L-GET is an end termination kit with LED signal lamp. It is designed and manufactured to meet all relevant standards for industrial trace heating cable system in hazardous locations such as petrochemical plant, gas plant, ship and off-shore facilities. It consists of an Ex certified plastic termination enclosure and all necessary parts together with Ex d signal lamp assembly. It has a specially 'flip cover locks' technology for easy and time-saving connection with self-regulating heating cables on various sites.
Product name: Heating cable tail waterproof silicone seal
Product color: orange-red
Product use: Waterproof seal short-term temperature resistance 250°C
Long-term temperature resistance: 200℃
Product material: Silicone
Reusable: Yes
Applicable to waterproof sealing at the branch of cable core and tail end sealing protection
The explosion-proof terminal junction box is used at the end of the heating cable to reliably isolate the fracture of the heating cable from the outside world. The shell material is made of PMC plastic
Introduction/Description/Overview:
It is made of high-temperature resistant white PTFE fiberglass cloth and treated at high temperature. The product has the characteristics of good temperature resistance, strong adhesion, strong tear resistance, and melting resistance. It is used to tie the heating cable to the pipe. It is not used for stainless steel pipes or installations below 40°F (5℃).
Structural dimensions/outline dimensions:
Thickness 0.2mm, width 0.5 inches, length 20m
Applicable conditions/application areas/purposes and restrictions/usage conditions:
For stainless steel pipes, or installations below 40°F (5℃), maximum temperature resistance: 260℃.
Advantages/superiority:
The self-regulating heating cable automatically increases power as the ambient temperature decreases, and starts quickly. When the temperature rises, the power is reduced to avoid overheating, reduce operating costs, and the temperature is uniform. The self-regulating heating cable can be cut arbitrarily according to actual conditions, can be cross-overlapped, simple to install, and easy to maintain.
Introduction/Description/Overview:
It is made of high-temperature resistant white PTFE fiberglass cloth and treated at high temperature. The product has the characteristics of good temperature resistance, strong adhesion, strong tear resistance, and melting resistance. It is used to tie the heating cable to the pipe. It is not used for stainless steel pipes or installations below 40°F (5℃).
Structural dimensions/outline dimensions:
Thickness 0.2mm, width 0.5 inches, length 16.5m
Applicable conditions/application areas/purposes and restrictions/usage conditions:
For stainless steel pipes, or installations below 40°F (5℃), maximum temperature resistance: 260℃.
Advantages/superiority:
The self-regulating heating cable automatically increases power as the ambient temperature decreases, and starts quickly. When the temperature rises, the power is reduced to avoid overheating, reduce operating costs, and the temperature is uniform. The self-regulating heating cable can be cut arbitrarily according to actual conditions, can be cross-overlapped, simple to install, and easy to maintain.
HYB-YM30 heat-resistant pressure-sensitive adhesive tape, also known as fixed tape, is coated with a layer of special adhesive and aluminum film on the basis of glass fiber tape. The bandwidth is 20mm, and each roll is 30m. In the electric heating system, When the electric heating cable is installed, it is used to fix the electric heating cable along the radial direction of the pipeline. The equipped length depends on the outer diameter and length of the heating pipeline. The distance depends on the diameter of the pipeline, generally 0.5 ~ 0.8m. The amount of pressure-sensitive tape is generally taken as the circumference of the pipeline × the length of the pipeline × 8 (combined coefficient)
HYB-LB45 aluminum foil tape is coated with a layer of special adhesive on the aluminum foil tape. In the electric heating system, when the electric heating cable is installed, it is used to fix the electric heating cable along the direction of the electric heating cable and fully contact the heating object. Tracing heat and eliminating static electricity. The temperature sensing package of the thermostat is fixed for easy installation. Its main function is to fix the heating cable, increase the heat dissipation surface of the heating cable, and improve heat conduction. The bandwidth is 50mm, and each roll is 45m. The amount of aluminum foil tape used is 1.2 times of the designed electric heat tracing quantity.
HY-DBKX control box is a standard or non-standard distribution box for electric heating cable heating.
HY cast aluminum explosion-proof junction box is used for the connection of power lines and electric heating cables in explosion-proof areas. Usually fixed on the pipe. It is suitable for use in the explosive gas mixture T4 group field in the first and second areas of the factory after being matched with the electric heating belt. HY cast aluminum explosion-proof junction box can output unidirectionally or bidirectionally. Its housing is made of aluminum.
HYB-GK steel clip is composed of stainless steel band and adjusting screw or lock clip, which is used to fix accessories such as explosion-proof power junction box on the pipeline. The steel strip can be cut according to 1.1 times the actual fixed length of the pipe diameter.
HZ703 performance and use: aging resistance, acid and alkali resistance, high and low temperature resistance (-60 ℃ ~ 250 ℃). No corrosion, good insulation, waterproof, shockproof performance, especially for the insulation potting of electric heating appliances.